LAQUA 200 Series Handheld Meters

Eco-friendly, Shock & Scratch Resistant, Non-slip, One-handed Operation

Experience the future with unparalleled quality and ease of use at budget prices. Fully IP67 waterproof , ergonomically designed with all function keys in easy reach of one hand

LAQUA PH210 (pH/mV [ORP]/Temperature)

Features

  • Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)
  • 0.01 pH resolution
  • Offset and average slope display
  • Automatic / manual temperature compensation and temperature calibration function
  • ORP calibration option
  • °C & °F temperature readings
  • Auto log data; built-in memory can store up to 500 data
  • Auto shut-off (programmable: up to 30 minutes)
  • Auto stable, auto hold, and real time measurement modes
  • Calibration alarm (programmable: up to 90 days)
  • Built-in electrode holder allows 2 electrodes to be attached
  • Monochrome LCD with white LED backlight: 50 x 50 mm
  • Phono jack output for connecting meter to computer for software upgrade
  • Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
  • Powered by 2 x AA batteries
  • Packaged with electrode and calibration solutions in carrying case
  • 3 years meter warranty

Meter Kits Available

PH210-K

Package Details:

    • LAQUA PH210 pH/ORP/Temp meter
    • 2 x AA batteries
    • Manual and quick guide
    • 9652-10D plastic-body, gel-filled pH electrode with integrated temperature sensor
    • pH 4.01, 7.00, 10.01 buffers (60ml each)
    • Carrying case

    PH210-KN: Kit with pH 4.01 / 6.86 / 9.18 NIST buffers (60ml each) is available upon request.

LAQUA PH220 (pH/mV [ORP] /Temperature, PC/Printer output)

Features

    • Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)
    • 0.01 pH resolution
    • Offset and average slope display
    • Automatic / manual temperature compensation and temperature calibration function
    • ORP calibration option
    • °C & °F temperature readings
    • With real-time clock and date/time stamp for GLP compliance
    • Auto log data; built-in memory can store up to 1000 data
    • Auto shut-off (programmable: up to 30 minutes)
    • Auto stable, auto hold, and real time measurement modes
    • Calibration alarm (programmable: up to 90 days)
    • Built-in electrode holder allows 2 electrodes to be attached
    • Monochrome LCD with white LED backlight: 50 x 50 mm
    • Phono jack output for connecting meter to computer via PC (USB) cable for data collection and software upgrade and to printer via printer (RS232) cable for printout
    • Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
    • Powered by 2 x AA batteries
    • Packaged with electrode and calibration solutions in carrying case
    • 3 years meter warranty
LAQUA EC210 (Conductivity, Salinity, Resistivity, TDS)

Features

  • Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration
  • Adjustable reference temperature and temperature coefficient
  • Adjustable cell constant and selectable measurement unit
  • Automatic / manual temperature compensation and temperature calibration function
  • Conductivity and total dissolved solids (TDS) conversion
  • Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl
  • Two (2) salinity calibration curves: NaCl, Seawater
  • °C & °F temperature readings
  • Auto log data; built-in memory can store up to 500 data
  • Auto stable, auto hold, and real-time measurement modes
  • Auto shut-off (programmable: up to 30 minutes)
  • Monochrome LCD with white LED backlight: 50 x 50 mm
  • Phono jack output for connecting the meter to computer (for software upgrade only)
  • Powered by 2 x AA batteries
  • Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
  • Packaged with electrode and calibration solutions in carrying case
  • 3 years meter warranty

Meter Kit Available

EC210-K

  

Package Details:

  • LAQUAact EC210 Cond/TDS/Res/Sal/Temp meter
  • 2 x AA batteries
  • Manual and quick guide
  • 9383-10D plastic-body, Ti/Pt black conductivity probe (k=1.0) with integrated temperature sensor
  • 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm conductivity standard solutions (60ml each)
  • Carrying case

Manufactured by HORIBA Advanced Technologies

LAQUA EC220 (Conductivity, Resistivity, Salinity, TDS, PC/Printer output)

Features

  • Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration
  • Adjustable reference temperature and temperature coefficient
  • Adjustable cell constant and selectable measurement unit
  • Automatic / manual temperature compensation and temperature calibration function
  • Conductivity and total dissolved solids (TDS) conversion
  • Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl
  • Two (2) salinity calibration curves: NaCl, Seawater
  • °C & °F temperature readings
  • With real-time clock and date/time stamp for GLP compliance
  • Auto log data; built-in memory can store up to 1000 data
  • Auto stable, auto hold, and real-time measurement modes
  • Auto shut-off (programmable: up to 30 minutes)
  • Monochrome LCD with white LED backlight: 50 x 50 mm
  • Phono jack output for connecting the meter to computer via PC (USB) cable for data collection and software upgrade and to printer via printer (RS232) cable for printout
  • Powered by 2 x AA batteries
  • Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
  • Packaged with electrode and calibration solutions in carrying case
  • 3 years meter warranty

Meter Kit Available

EC220-K

  

Package Details:

  • LAQUAact EC220 Cond/TDS/Res/Sal/Temp meter
  • 2 x AA batteries
  • Manual and quick guide
  • 9383-10D plastic-body, Ti/Pt black conductivity probe (k=1.0) with integrated temperature sensor
  • 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm conductivity standard solutions (60ml each)
  • Carrying case

Manufactured by HORIBA

LAQUA DO210 (Dissolved Oxygen, Temperature)

Features

  • Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation
  • 0.01 mg/L or 0.1% DO resolution
  • Compensates salinity, temperature, and atmospheric pressure
  • Allows up to 2 calibration points using galvanic DO electrode
  • °C & °F temperature readings
  • Auto log data; built-in memory can store up to 500 data
  • Auto stable, auto hold, and real-time measurement modes
  • Auto shut-off (programmable: up to 30 minutes)
  • Built-in electrode holder allows 2 electrodes to be attached
  • Monochrome LCD with white LED backlight: 50 x 50 mm
  • Phono jack output for connecting the meter to computer (for software upgrade only)
  • Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
  • Powered by 2 x AA batteries
  • Packaged with galvanic electrode in carrying case
  • 3 years meter warranty

Meter Kit Available

DO210-K

  

Package Details:

  • LAQUA DO210 DO/Temp meter
  • 2 x AA batteries
  • Manual and quick guide
  • 9552-20D Galvanic DO probe with integrated temperature sensor, 2m cable
  • Carrying case

Manufactured by HORIBA

LAQUA DO220 (Dissolved Oxygen, Temperature, PC/Printer output)

Features

  • Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation
  • 0.01 mg/L or 0.1% DO resolution
  • Compensates salinity, temperature, and atmospheric pressure
  • Allows up to 2 calibration points using galvanic DO electrode
  • °C & °F temperature readings
  • With real-time clock and date/time stamp for GLP compliance
  • Auto log data; built-in memory can store up to 1000 data
  • Auto stable, auto hold, and real-time measurement modes
  • Auto shut-off (programmable: up to 30 minutes)
  • Built-in electrode holder allows 2 electrodes to be attached
  • Monochrome LCD with white LED backlight: 50 x 50 mm
  • Phono jack output for connecting meter to computer via PC (USB) cable for data collection and software upgrade and to printer via printer (RS232) cable for printout
  • Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
  • Powered by 2 x AA batteries
  • Packaged with galvanic electrode in carrying case
  • 3 years meter warranty

Meter Kit Available

DO220-K

  

Package Details:

  • LAQUA DO220 DO/Temp meter
  • 2 x AA batteries
  • Manual and quick guide
  • 9552-20D Galvanic DO probe with integrated temperature sensor, 2m cable
  • Carrying case

Manufactured by HORIBA

LAQUA PC210 (pH/mV [ORP], Cond/TDS/Salinity/Resistivity)

Features

  • Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)
  • 0.01 pH resolution
  • Offset and average slope display
  • ORP calibration option
  • Automatic / manual temperature compensation and temperature calibration function
  • Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration
  • Adjustable reference temperature and temperature coefficient
  • Adjustable cell constant and selectable measurement unit
  • Conductivity and total dissolved solids (TDS) conversion
  • Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl
  • Two (2) salinity calibration curves: NaCl, Seawater
  • Auto log data; built-in memory can store up to 500 data
  • Auto shut-off (programmable: up to 30 minutes)
  • Auto stable, auto hold, and real time measurement modes
  • Calibration alarm (programmable: up to 90 days)
  • Built-in electrode holder allows 2 electrodes to be attached
  • Monochrome LCD with white LED backlight: 50 x 50 mm
  • Phono jack output for connecting the meter to computer for software upgrade only
  • Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
  • Powered by 2 x AA batteries
  • Packaged with electrodes and calibration solutions in carrying case
  • 3 years meter warranty

Meter Kit Available

PC210-K

  

Package Details:

  • LAQUA PC210 dual channel pH/ORP/Cond/TDS/Res/Sal/Temp meter
  • 2 x AA batteries
  • Manual and quick guide
  • 9652-10D plastic-body, gel-filled pH electrode with integrated temperature sensor
  • 9383-10D plastic-body, Ti/Pt black, conductivity probe (k=1.0) with integrated temperature sensor
  • pH 4.01 and 7.00 buffers, 1413µS/cm and 12.88 mS/cm conductivity solutions (60ml each)
  • Electrode adapter
  • Carrying case

PC210-KN: Kit with pH 4.01 and 6.86 NIST buffers (60ml each) is available upon request.

Manufactured by HORIBA

LAQUA PC220 (pH/mV [ORP], Cond/TDS/Salinity/Resistivity, PC/Printer out)

Features

  • Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)
  • 0.01 pH resolution
  • Offset and average slope display
  • ORP calibration option
  • Automatic / manual temperature compensation and temperature calibration function
  • Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration
  • Adjustable reference temperature and temperature coefficient
  • Adjustable cell constant and selectable measurement unit
  • Conductivity and total dissolved solids (TDS) conversion
  • Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl
  • Two (2) salinity calibration curves: NaCl, Seawater
  • With real-time clock and date/time stamp for GLP compliance
  • Auto log data; built-in memory can store up to 1000 data
  • Auto shut-off (programmable: up to 30 minutes)
  • Auto stable, auto hold, and real time measurement modes
  • Calibration alarm (programmable: up to 90 days)
  • Built-in electrode holder allows 2 electrodes to be attached
  • Monochrome LCD with white LED backlight: 50 x 50 mm
  • Phono jack output for connecting meter to computer via PC (USB) cable for data collection and software upgrade and to printer via printer (RS232) cable for printout
  • Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
  • Powered by 2 x AA batteries
  • Packaged with electrodes and calibration solutions in carrying case
  • 3 years meter warranty

Meter Kit Available

PC220-K

  

Package Details:

  • LAQUA PC220 dual channel pH/ORP/Cond/TDS/Res/Sal/Temp meter
  • 2 x AA batteries
  • Manual and quick guide
  • 9652-10D plastic-body, gel-filled pH electrode with integrated temperature sensor
  • 9383-10D plastic-body, Ti/Pt black, conductivity probe (k=1.0) with integrated temperature sensor
  • pH 4.01 and 7.00 buffers, 1413µS/cm and 12.88 mS/cm conductivity solutions (60ml each)
  • Electrode adapter
  • Carrying case

PC220-KN: Kit with pH 4.01 and 6.86 NIST buffers (60ml each) is available upon request.

Manufactured by HORIBA

LAQUA PD210 (pH/mV [ORP], Dissolved Oxygen)

Features

  • Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)
  • 0.01 pH resolution
  • Offset and average slope display
  • Automatic / manual temperature compensation and temperature calibration function
  • ORP calibration option
  • Dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation
  • 0.01 mg/L or 0.1% DO resolution
  • Compensates salinity, temperature, and atmospheric pressure
  • Up to 2 DO calibration points
  • Auto log data; built-in memory can store up to 500 data
  • Auto shut-off (programmable: up to 30 minutes)
  • Auto stable, auto hold, and real time measurement modes
  • Calibration alarm (programmable: up to 90 days)
  • Built-in electrode holder allows 2 electrodes to be attached
  • Monochrome LCD with white LED backlight: 50 x 50 mm
  • Phono jack output for connecting the meter to computer for software upgrade
  • Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
  • Powered by 2 x AA batteries
  • Packaged with electrodes and calibration solutions in carrying case
  • 3 years meter warranty

Meter Kit Available

PD210-K

  

Package Details:

  • LAQUA PD210 dual channel pH/ORP/DO/Temp meter
  • 2 x AA batteries
  • Manual and quick guide
  • 9652-20D plastic-body, gel-filled pH electrode with integrated temperature sensor, 2m cable
  • 9552-20D Galvanic DO probe with integrated temperature sensor, 2m cable
  • pH 4.01, 7.00, 10.01 buffers (60ml each)
  • Electrode adapter
  • Carrying case

PD210-KN: Kit with pH 4.01 / 6.86 / 9.18 NIST buffers (60ml each) is available upon request.

Manufactured by HORIBA

LAQUA PD220 (pH/mV [ORP], Dissolved Oxygen, PC/Printer output)

Features

  • Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)
  • 0.01 pH resolution
  • Offset and average slope display
  • Automatic / manual temperature compensation and temperature calibration function
  • ORP calibration option
  • Dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation
  • 0.01 mg/L or 0.1% DO resolution
  • Compensates salinity, temperature, and atmospheric pressure
  • Up to 2 DO calibration points
  • With real-time clock and date/time stamp for GLP compliance
  • Auto log data; built-in memory can store up to 1000 data
  • Auto shut-off (programmable: up to 30 minutes)
  • Auto stable, auto hold, and real time measurement modes
  • Calibration alarm (programmable: up to 90 days)
  • Built-in electrode holder allows 2 electrodes to be attached
  • Monochrome LCD with white LED backlight: 50 x 50 mm
  • Phono jack output for connecting the meter to computer via PC (USB) cable for data collection and software upgrade and to printer via printer (RS232) cable for printout
  • Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
  • Powered by 2 x AA batteries
  • Packaged with electrodes and calibration solutions in carrying case
  • 3 years meter warranty

Meter Kit Available

PD220-K

  

Package Details:

  • LAQUA PD220 dual channel pH/ORP/DO/Temp meter
  • 2 x AA batteries
  • Manual and quick guide
  • 9652-20D plastic-body, gel-filled pH electrode with integrated temperature sensor, 2m cable
  • 9552-20D Galvanic DO probe with integrated temperature sensor, 2m cable
  • pH 4.01, 7.00, 10.01 buffers (60ml each)
  • Electrode adapter
  • Carrying case

PD220-KN: Kit with pH 4.01 / 6.86 / 9.18 NIST buffers (60ml each) is available upon request.

Manufactured by HORIBA